Re: Обновление ESXi 4.1 до 5.1. Проблема с Nexus 1000v

$
0
0

Пару часов назад решил эту проблему. Решение находится здесь: https://communities.vmware.com/message/2176033#2176033

Хосты добавились к нексусу без проблем, но появилась новая проблема.

Нексус пишет в лог следующее:

2014 May  7 05:04:47 Nexus1000-V %PORT-PROFILE-2-INTERFACE_QUARANTINED: Interface Ethernet17/6 has been quarantined due to Cmd Failure

2014 May  7 05:04:47 Nexus1000-V %PORT-PROFILE-2-INTERFACE_QUARANTINED: Interface Ethernet17/5 has been quarantined due to Cmd Failure

 

Nexus1000-V# sh interface ethernet 17/6 brief

 

--------------------------------------------------------------------------------

Ethernet      VLAN   Type Mode   Status  Reason                   Speed     Port

Interface                                                                   Ch #

--------------------------------------------------------------------------------

Eth17/6       1      eth  pvlan  down    NoPortProfile              auto

 

 

У меня на данный момент два ESXi 5.1 подключены к NExus1000v.

 

Nexus1000-V# show port-profile sync-status

 

Ethernet16/5

port-profile: SMEV-Uplinks

interface status: quarantine

sync status: out of sync

cached commands:

errors:

    cached command failed

recovery steps:

    unshut interface

 

Ethernet16/6

port-profile: SMEV-Uplinks

interface status: quarantine

sync status: out of sync

cached commands:

errors:

    cached command failed

recovery steps:

    unshut interface

 

Ethernet17/5

port-profile: SMEV-Uplinks

interface status: quarantine

sync status: out of sync

cached commands:

errors:

    cached command failed

recovery steps:

    unshut interface

 

Ethernet17/6

port-profile: SMEV-Uplinks

interface status: quarantine

sync status: out of sync

cached commands:

errors:

    cached command failed

recovery steps:

    unshut interface

 

 

Очевидно что рекомендация с не помогает.

 

 

port-profile type ethernet SMEV-Uplinks
  vmware port-group
  switchport mode private-vlan trunk promiscuous
  switchport private-vlan trunk allowed vlan 3,51-72,75-76,101,105,108
  switchport private-vlan mapping trunk 51 920-929
  switchport private-vlan mapping trunk 58 940-949
  switchport private-vlan mapping trunk 71 950-959
  switchport private-vlan mapping trunk 59 960-969
  switchport private-vlan mapping trunk 72 970-979
  switchport private-vlan mapping trunk 75 980-989
  channel-group auto mode on mac-pinning
  no shutdown
  system vlan 52
  state enabled

 

 

Пока не разобрался. Есть предположения?